Property Baseline is 1nspecT’s pre-inspection snapshot of a property. It pulls public dataset information from the address and presents it in two subsections: Site Conditions (physical hazards and climate) and Construction-era materials (what materials are typical for the home’s build year and region). The baseline is intelligence for the inspector and the office, not content for the client report. The AI reads it when drafting narratives, especially for shrink-swell, climate zone and flood zone contexts.

Where you see it

  • Mobile inspection setup (first screen when the inspector taps into a job)
  • Order Creation Wizard (property step) — section header reads Property Baseline
  • Inspection Details (web, History tab) — header: AI Property Baseline Report
  • Pull Property Baseline button on the Inspection Details tab of the inspection, to re-pull if the property was edited

Site Conditions subsection

Every row cites its source inline: The panel header reads Site Conditions with sources listed inline: USDA NRCS SSURGO · FEMA NFHL · EPA Radon Zones · IRC R301.2(6) · DOE/PNNL Climate Zones.

What each tells the inspector

  • Shrink-swell potential — the biggest driver of foundation movement risk. High shrink-swell soils (LEP > 6) call for close attention to grading, drainage and visible movement indicators.
  • FEMA flood zone — Zone A, AE, VE and similar require extra attention to grading, drainage, and anything the inspector should flag or disclaim.
  • EPA radon zone — Zone 1 counties justify recommending a radon test; Zone 3 counties typically don’t.
  • Termite pressure — Moderate-to-Heavy or Very Heavy zones justify thorough examination for signs of past or current infestation and installation of termite shields.
  • Climate zone + attic insulation — The recommended attic insulation (R-38 in Zone 2A for new construction per the 2024 IECC) is the baseline for grading what you observe. AI narratives on insulation findings recommend adding insulation “to achieve the recommended level for this climate region”. They don’t quote an R-value.

Construction-era materials subsection

Separate section labeled Construction-era materials. Each row is a material typical for the property’s build year and region, with its prevalence and severity. The panel header reads Construction-era materials with the subheader “Typical for this build year and region — candidates to look for, not observations at this property.” The materials matrix is 1nspecT-maintained (not a public dataset) and based on inspection-industry service-life guidance and historical construction practice.

Pull Property Baseline

In the Order Creation Wizard the baseline is a button you click, not an automatic step. If a property is edited later (year built changed, foundation type corrected), click 🤖 Pull Property Baseline on the Inspection Details tab to re-pull with the updated inputs.

Visibility

Property Baseline is visible only to subscribers (owner, admin, inspector). It is not shown to the client and does not print on the published report. The AI reads it internally to frame narratives but does not cite it verbatim.