Where the checks live
Open the Report Workspace: Inspections top nav › the order › the inspection › Report Workspace. The workspace has two tabs across the top:- Findings — every finding on the inspection, with ratings, narratives, photos and the Narrative Review Panel
- Legal Preamble — the SoP-required legal preamble
The Narrative Review Panel
As you work through the report, the Narrative Review Panel evaluates each narrative against the SoP’s writing rules and surfaces any issue:- Numbers that don’t come from captured readings
- Causes stated as certain where the SoP requires hedging
- Jargon that should be plain-language
- Hedging dropped by the AI that your field note included
- Specialist rules for HVAC, electrical, plumbing, site and grading, gas and fire safety
- A passing finding with no Recommendation when your field note asks for an action (see below)
- A narrative written by the backup AI model, whose headline tag needs a second look (see below)
- Headline and movement wording, punctuation, and findings that may belong in the summary (see below)
- Recommendation wording and equipment data (see below)
Passing finding is missing the action your note asks for
This flag is for review only and never blocks Publish. It appears when a passing finding tagged Acceptable Performance has no Recommendation, but your field note asks for an action (“recommend”, “replace”, “repair”, “service”, “monitor”, “adjust”, “clean” and similar). The message reads: “This passing finding has no Recommendation, but the field note asks for an action. Add the Recommendation the note asks for.” If the note doesn’t ask for an action, the draft gets “No action is required at this time.” as the Recommendation automatically.Drafted by the backup AI
If the main AI model is unavailable when a narrative is drafted, a backup model writes it instead, so the draft still arrives. This is rare. The finding then shows the flag Drafted by the backup AI — check the Safety / Structural tag, with the message: “Drafted by the backup AI model while Gemini was unavailable. Check the headline tag — especially whether it should be a Safety or Structural Deficiency — before publishing.” The backup model isn’t tuned as closely to your Standard of Practice as the main model, so check the headline tag, especially whether it should be a Safety or Structural Deficiency. Fix the tag if it’s wrong. The flag is for review only and never blocks Publish. The flag shows only in the web Report Workspace, not in the mobile app.Headline, movement and summary flags
A finding gets at most one of the three summary reminders.
Recommendation and equipment flags
A Recommendation names the trade and one direct action, for example “A qualified contractor should repair the caulking as needed.” Use “should evaluate … and repair as needed” only when the cause or scope is unknown. None of these flags blocks Publish.Completeness gate
Publish is a hard gate. Before Publish will accept the report, the completeness gate checks:- Subsection ratings (every subsection that requires a rating has one)
- Required fields. On TREC 7-6 templates these include Location of water meter and Location of main water supply valve.
- The FPO check
- Every finding has either a narrative, or an explicit “publish without narrative” sign-off
Findings without a narrative
If a finding has no narrative when you try to Publish, the Publish action refuses with a clear message:“Cannot publish — N finding(s) have no narrative. Draft them (AI Draft & Polish), or choose ‘Publish without narrative’ for each one in the review panel.”Two ways to resolve:
- Draft the narrative. Run AI Draft & Polish (drafts every eligible finding, then Polish Report) or draft the finding individually.
- Publish without narrative. For a finding that doesn’t need a narrative (an observation that’s already documented in a related finding, say), open the review panel for that finding and sign off on Publish without narrative. The sign-off is recorded against the caller on the server, so there’s an audit trail of who approved publishing without a narrative on which finding.
Aged-systems check
Separately from narrative review, 1nspecT runs an aged-systems check that looks at equipment age fields (HVAC units, water heaters) and flags any equipment past its typical service life that doesn’t have a related finding. This is informational, not a publish blocker: it’s a prompt to confirm you intended to publish without flagging the aged equipment.Aged Equipment Advisory findings
A finding about aged equipment, such as a water heater or air handler, is headed Aged Equipment Advisory. It’s informational, not a deficiency. The tag is applied when the caption:- is “Aged Equipment Advisory”;
- says the unit is past, beyond or exceeds its expected, typical or estimated service life;
- or is an age caption such as “Water Heater Age — 14”, which the phone suggests when an age field is above your template’s range.
Preview PDF before publishing
Use Preview PDF to generate the PDF without locking the inspection. It warns you upfront if any publish blockers exist, but it still generates the PDF so you can walk the client through a draft, catch anything the review panel missed, or review layout. The real Publish action is blocked until the required items are resolved. (Not to be confused with Publish Report, which does publish the report to the client and locks that version.)What Publish actually does
Once every required item is resolved, Publish:- Locks the inspection (no more edits without a Republish)
- Uploads the final PDF to secure storage
- Generates the client’s permanent report URL slug and the agent’s view
- Saves a version record for this publish (version number and publish time)
- Fires the matching workflow trigger (
report.publishedwhen the order is paid, which sends the configured delivery emails, or the payment-pending variant when it is unpaid)